Condec Source 3000 User Manual

Browse online or download User Manual for Equipment Condec Source 3000. Condec Source 3000 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 22
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
65546
Source 3000
Self-Contained Pressure Source Console
Operation and
Maintenance Manual
Page view 0
1 2 3 4 5 6 ... 21 22

Summary of Contents

Page 1 - Maintenance Manual

65546 Source 3000 Self-Contained Pressure Source Console Operation and Maintenance Manual

Page 2

6 Source 3000 Operation and Maintenance Manual 3.2.3 Installing New Nitrogen Cylinder Assembly (PN 65622) Tools required: 7/16" wrenchPhillips

Page 3 - Contents

Maintenance 7 1. Secure the manifold by its center portion, in a bench vise, with the valve knobs pointing upward.2. Using the .061" hex wrench,

Page 4

8 Source 3000 Operation and Maintenance Manual 3.2.7 ORION 2C Manifold, Vernier Control Reassembly Tools required: tube fluorinated Krytox grease (PN

Page 5 - 1.0 Introduction

Maintenance 9 9. Mount the manifold body (16) in a vise. For the pressure and vent valves only, torque the needle/housingassembly to 325 in-lb. using

Page 6 - DISCONNECT)

10 Source 3000 Operation and Maintenance Manual knob clockwise until the isolation valve is slightly snug. To avoid damage to the seat, do not useex

Page 7 - 2.0 Operation

Maintenance 11 3.2.13 Panel Gage Removal Tools required: Phillips screwdriver7/16" wrench9/16 " wrench 1. Vent any remaining gas from the n

Page 8 - 2.2 Initial Setup

12 Source 3000 Operation and Maintenance Manual 3.2.16 Port 1, Port 2 and Fill Port Filter (PN 54188) The port filter is a sintered element filter whi

Page 9 - 3.0 Maintenance

Maintenance 13 4. Remove the male reducing adapter/run tee assembly from the check valve.5. Remove the check valve from the female elbow fitting. Remo

Page 10

14 Source 3000 Operation and Maintenance Manual Figure 3-1. Standard Pneumatic Regulator (PN 65455)Figure 3-2. Nitrogen Inlet Check Valve Assembly (P

Page 11 - Maintenance

Maintenance 15 Figure 3-3. Orion 2C, Exploded View153220124241OR14OR42412913271725/2X25/2X23/2X34524/3X333421101183027312897312897830271961826/2X3821

Page 12

2 Source 3000 Operation and Maintenance Manual

Page 13

Specifications 16 4.0 Specifications Pressure Specifications: Pressure range: Based on vendor’s electronicsAvailable pressure calibrations:Gage only, a

Page 14

17 Source 3000 Operation and Maintenance ManualSource 3000 Warranty and Return PolicyIf possible, please save original packing material which is speci

Page 15

Specifications 18Source 3000 Return Material Authorization FormThe repair lab is also equipped to do calibrations on our calibrators and pressure stan

Page 16

Copyright © 2003 Rice Lake Weighing Systems. All rights reserved. Printed in the United States of America. Specifications subject to change without no

Page 17

ii Source 3000 Operation and Maintenance Manual

Page 18

Introduction 1 About This Manual The Source 3000 is a portable, self-contained pneumatic pressure console with precision vernier. A rugged,compact in

Page 19

2 Source 3000 Operation and Maintenance Manual The heart of the Source 3000 are the two micro-metering valves and the vernier provided for control of

Page 20 - 4.0 Specifications

Operation 3 2.0 Operation 2.1 Pressure Cylinder Filling To initially fill or refill the internal pressure cylinder (3000 PSI max.) of the Source 3000,

Page 21

4 Source 3000 Operation and Maintenance Manual 2.2 Initial Setup To prepare for actual calibration usage, see Figure 2-2 below and proceed as follows

Page 22 - WEB SITE: www.4condec.com

Maintenance 5 3.0 Maintenance 3.1 Troubleshooting3.2 Maintenance Procedures This section outlines the mechanical repair procedures for the Source 300

Comments to this Manuals

No comments