Condec DLR334 User Manual

Browse online or download User Manual for Equipment Condec DLR334. Condec DLR334 User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - PRESSURE INDICATOR

PAGE 1 74845DLR334PRESSURE INDICATORDUPLEXSERIAL PROTOCOL

Page 2

PAGE 10 74845T TempD Diagnostic ;later! Pressure status (PSR command)DATA FORMAT: <stat>LENGTH: Fixed at 1 chara

Page 3 - 2.0 FULL DUPLEX PROTOCOL:

PAGE 11 74845! Cal Units DATA entry (UUE{} command) and recall ( UUR command)FORMAT: <unit1><unit 2>LENGTH: F

Page 4 - 5.0 RESPONSE:

PAGE 12 74845P2E{} / P2R = Port 2 serial setup.INE{} / INR = Input setup.TME{} / TMR = Time.DTE{} / DTR = Date.TIE{} /

Page 5

PAGE 13 7484502 3 07 8 12 16 17 3503 4 08 9 13 18 18 4004 5 09 1014201945EXAMPLE: A filter setting of 14 would be *FLE{1

Page 6 - 8.0 COMMAND CODE SUMMARY:

PAGE 14 7484514.8 TIME/DATE SETUP:COMMAND: TIE/TIRDATA FORMAT: <t1>|<t2>|<t3>LENGTH: Fixed at 5 charact

Page 7

PAGE 15 74845trip = Setpoint (Trip Point) Option select.disp = Display indicationrecall = Trip point status.TRIP 1 TRIP 2t

Page 8 - RESPONSE DATA:

PAGE 16 74845! TEMPERATURE CORRECTIONS DATA ENTRY AND RECALL:COMMANDS: D1E{}/D1R and D2E{}/D2RDATA FORMAT (1): <zr>

Page 9

PAGE 17 74845DTE / DTR = Date.DxE / DxR = Temperature Corrections entry and recall (x=1 or 2)FLE / FLR = Filter setup.HC

Page 10 - D Diagnostic ;later

PAGE 2 74845CONTENTS1.0 GENERAL……………………………………………………………… 32.0 FULL DUPLEX PROTOCOL……………………………………….… 33.0 COMMAND CODE <

Page 11 - 14.2 COMMANDS:

PAGE 3 74845DLR334 PRESSURE DUPLEX SERIAL PROTOCOL1.0 GENERAL:! This document applies to the basic Pressure program KDG

Page 12 - 14.4 FILTER SETUP:

PAGE 4 74845♦ General commands (Zero, etc.).♦ Display commands (Min,Max, etc.).♦ Pressure calibration (Zero Cal, etc.)

Page 13

PAGE 5 74845! Commands received as valid but that can not be performed: A valid command in the Echo or Ack/Nak mode that

Page 14

PAGE 6 74845RESPONSE VALID ENTRY INVALID ENTRY CAN NOT PERFORM(NONE) = (NONE) (NONE) (NONE)(ECHO) =

Page 15 - TEMPERATURE CALIBRATION:

PAGE 7 74845COMMAND CODE SUMMARY TABLE IICOMMAND RESPONSE D DESCRIPTIONOSR OSR {o1|o2} 3 Output status recall.

Page 16 - CPE / CPR = Capacity

PAGE 8 74845COMMAND CODE SUMMARY TABLE IICOMMAND RESPONSE D DESCRIPTIONTIR TIR {time/date} Time and Date setup recall. PA

Page 17 - UxD = Select units

PAGE 9 74845C CmH2OMmmH2O4ΕCVVAC (SPECIAL)D inHgOΕCNPASCALE Kg/cm2O (SPARE)F FtseaH2OPPSIG inH2O60F Q (SPARE)H inH2O68F R

Comments to this Manuals

No comments